Home / Solution - Embodied Intelligence

Solution - Embodied Intelligence

Solutions · Embodied Intelligence

Compute Infrastructure
for Physical AI.

The cooling and power architecture behind physical AI must be as relentless as the workload.

Discuss Your AI Compute Needs

The compute challenge behind robotics.

Extreme Thermal Density

GB200, MI400X, and custom ASICs produce thermal loads that exceed air-cooled capacity at rack scale.

Sustained Utilization

Infrastructure must maintain thermal stability under 100% GPU utilization without throttling or downtime.

Time-to-Compute Pressure

Teams cannot wait 18 months for facility construction when competitors are already training on next-gen hardware.

EPC Solution

High-density compute. Deploy in weeks.

Each modular block ships factory-integrated with power, closed-loop hydro-cooling, racks, and monitoring — fully wired and tested. The architecture supports both air-cooled and liquid cold-plate accelerator platforms in the same facility. Mixed workloads run as hardware generations evolve.

· Up to 1 MW per modular block · Closed-loop hydro-cooling — no external water · Mixed air/liquid cold-plate support
Engineers commissioning hydro-cooled accelerator platform racks inside a CoolSpace modular data center

Built for physical AI workloads.

Sustained Thermal Stability

Closed-loop hydro-cooling maintains stable temperatures under 100% GPU utilization — no throttling, no thermal cycling.

Weeks, Not Years

Factory pre-integration eliminates site construction timelines. A complete compute environment arrives as a single deployable block.

Hardware-Agnostic Architecture

Air-cooled and liquid cold-plate platforms in the same block — the infrastructure adapts as hardware evolves.

Scale Without Redesign

Add identical blocks as compute requirements grow — from proof-of-concept clusters to full-scale training.

Infrastructure Parameters

Modular block specifications.

Cooling MethodClosed-loop hydro-cooling
Form FactorStandard 40HQ / 20HQ ISO container
IT Load CapacityUp to 1 MW per block (CoolBase-1080A/W)
PUE (Standard)< 1.2
PUE (Free Cooling)< 1.05
Power InputMedium-voltage direct input supported
GPU CompatibilityNVIDIA GB200, H200, AMD MI400X, custom ASICs
Cooling ModesAir-cooled and liquid cold-plate accelerator platforms
Deployment ModelFactory pre-integrated, plug-and-deploy
UtilizationSustained 100% GPU load without throttling
High-density GPU rack with hydro-cooling manifolds inside CoolSpace modular block
Robotic arm in testing environment powered by edge inference compute

Hydro-cooled accelerator platform cluster · Edge inference for autonomous systems

Build your AI compute infrastructure.

Share your workload profile and CoolSpace engineering will configure a modular solution within days.