Solution - Embodied Intelligence

Solutions · Embodied Intelligence

Compute Infrastructure
for Physical AI.

The cooling and power architecture behind physical AI must be as relentless as the workload.

Discuss Your AI Compute Needs→

The compute challenge behind robotics.

Extreme Thermal Density

GB200, MI400X, and custom ASICs produce thermal loads that exceed air-cooled capacity at rack scale.

Sustained Utilization

Infrastructure must maintain thermal stability under 100% GPU utilization without throttling or downtime.

Time-to-Compute Pressure

Teams cannot wait 18 months for facility construction when competitors are already training on next-gen hardware.

EPC Solution

High-density compute. Deploy in weeks.

Each modular block ships factory-integrated with power, closed-loop hydro-cooling, racks, and monitoring — fully wired and tested. The architecture supports both air-cooled and liquid cold-plate accelerator platforms in the same facility. Mixed workloads run as hardware generations evolve.

· Up to 1 MW per modular block · Closed-loop hydro-cooling — no external water · Mixed air/liquid cold-plate support
Engineers commissioning hydro-cooled accelerator platform racks inside a CoolSpace modular data center

Built for physical AI workloads.

Sustained Thermal Stability

Closed-loop hydro-cooling maintains stable temperatures under 100% GPU utilization — no throttling, no thermal cycling.

Weeks, Not Years

Factory pre-integration eliminates site construction timelines. A complete compute environment arrives as a single deployable block.

Hardware-Agnostic Architecture

Air-cooled and liquid cold-plate platforms in the same block — the infrastructure adapts as hardware evolves.

Scale Without Redesign

Add identical blocks as compute requirements grow — from proof-of-concept clusters to full-scale training.

Infrastructure Parameters

Modular block specifications.

Cooling MethodClosed-loop hydro-cooling
Form FactorStandard 40HQ / 20HQ ISO container
IT Load CapacityUp to 1 MW per block (CoolBase-1080A/W)
PUE (Standard)< 1.2
PUE (Free Cooling)< 1.05
Power InputMedium-voltage direct input supported
GPU CompatibilityNVIDIA GB200, H200, AMD MI400X, custom ASICs
Cooling ModesAir-cooled and liquid cold-plate accelerator platforms
Deployment ModelFactory pre-integrated, plug-and-deploy
UtilizationSustained 100% GPU load without throttling
High-density GPU rack with hydro-cooling manifolds inside CoolSpace modular block
Robotic arm in testing environment powered by edge inference compute

Hydro-cooled accelerator platform cluster · Edge inference for autonomous systems

Build your AI compute infrastructure.

Share your workload profile and CoolSpace engineering will configure a modular solution within days.