AI Data Centers
Crypto Infrastructure
AI Data Centers
Crypto Infrastructure
CoolBase-270A/W is a pre-fabricated outdoor AIDC unit delivering 270 kW of IT load in a stacked 20HQ form factor. Power distribution, UPS, CDU, CRAC, and DCIM are pre-integrated in a single block — cooling station above, IT pod below.
The CoolBase-270A/W features an integrated architecture that mounts the cooling station directly above the IT pod within a standard 20ft container. The lower compartment houses a fully consolidated infrastructure suite, including power distribution, UPS, CDU, CRAC, and DCIM. This all-in-one design ensures rapid deployment by delivering a unified footprint rather than fragmented components. Furthermore, we provide customized cooling solutions tailored to your specific needs. Built on a unified hardware platform and CDU topology, we can tailor the system to your exact needs—whether you require an air-cooled configuration, a hydro-cooled setup, or a hybrid solution compatible with both. The cooling distribution unit and rack manifolds are designed to deliver liquid when you need it, and fall back to built-in CRAC air cooling when you don't. The pod stays the same. Built-in CRAC units maintain constant ambient inside the pod. Ideal for moderate-density deployments, edge sites, and locations where liquid infrastructure is not yet ready. Integrated CDU with primary/secondary loop delivers direct-to-chip cooling for higher-density accelerator platforms. Closed-loop, leak-monitored, ready for higher power density. Four things we engineered into this unit so you don't have to integrate them on site. Cooling station above, IT pod below — in one 20HQ form factor. One delivery, one placement, one commissioning. Connect standard dual-feed utility power, and the pod is rack-ready. 2N CDU, N+1 power modules, dual utility feeds — every critical subsystem ships redundant inside the pod. Power, thermal, security and SLA on a single dashboard. Real-time alerts, automated reports, remote O&M ready. The lower bay of the 20HQ packs the full AIDC infrastructure stack into a single coordinated system: dual-feed power distribution, modular UPS with N+1 power modules, a 2N redundant CDU, built-in CRAC for constant ambient temperature, and an integrated DCIM control center. One cabinet row, one commissioning sequence, one set of telemetry. Every subsystem arrives pre-tested, pre-wired, and pre-mapped to the DCIM dashboard — so site work is placement, connection, and power-on. Pre-engineered, pre-tested, and pre-documented. Detailed mechanical, electrical, and thermal drawings available under NDA. Edge site, branch deployment, or a stacked facility rollout — share your compute, density, and utility profile. Our engineers will return a CoolBase-270A/W configuration, footprint, and timeline in days.An entire AI data center,in a single
stacked 20HQ.
Stacked Architecture. Fully Integrated. Site-Ready.
Air or hydro. One platform.
Air-Cooled Configuration
Hydro-Cooled Configuration
Compact block. Complete infrastructure.
Stacked, single-block
Low-voltage plug-in
Redundancy integrated
DCIM out of the box
Everything you need, integrated into the lower bay.
CoolBase-270A/W at a glance.
Tell us your compute profile. We'll configure your 270A/W block.